top of page

Introducing the IQmark Digital Spirometer, a remarkable advancement in Spirometry weighing only 10 oz. This innovative spirometer from Midmark meets or surpasses the rigorous standards set by the American Thoracic Society and is designed for ease of use. It provides all the essential measurements required from a diagnostic spirometer, including the recommended FEV6 by the NLHEP.

The Midmark IQmark Digital Spirometer uses disposable pneumotach mouthpieces, minimizing the chances of patient cross-contamination. 

The IQmark Digital Spirometer allows you to conduct FVC, VC, and MVV tests, and can produce full-page reports on standard 8 1/2 x 11 paper. Pre- and Post-Bronchodilator tests can be easily performed for both you and your patients. The spirometer utilizes a Disposable Pneumotach Mouthpiece to minimize the risk of patient cross-contamination during testing, ensuring safety and convenience. Additionally, utilizing the spirometer's data with smoking-cessation programs can enhance the success rate of participants.

This cutting-edge spirometer also provides the functionality of automatically reporting a patient's Lung Age and COPD Risk by entering their smoking history into the IQmark Digital Spirometer. This information can be invaluable in illustrating the current physical condition of a patient's lungs.

We understand that many medical offices are either in search of Electronic Medical Records (EMR) software packages or have already integrated an EMR into their practices. To address this, Midmark has developed an integration software solution that allows EMRs to directly acquire diagnostic data into their database. Reach out to your Midmark representative to determine whether your EMR is currently integrated or to discuss future integration solutions.

The accuracy and precision of the IQmark Digital Spirometer have been validated at LDS Hospital in Salt Lake City, as evidenced by the results compared to the spirometry recommendations of the ATS Standardization of Spirometry, 1994 Update.

Real-Time Graphics including Flow-Volume and Volume-Time, along with customizable and preprogrammed 8.5 x 11 Full Size reports are just some of the exemplary features this spirometer offers.

The Midmark Iqmark - Digital Spirometry System is available for purchase in a 'seller refurbished' condition, which guarantees that it has undergone a thorough inspection, cleaning, and restoration process to ensure it functions optimally and looks great, even though it may not come in its original packaging. Rest assured, our dedicated biomedical staff rigorously tests and inspects all products and accessories before shipping. Additionally, our customer service and technical support teams stand ready to assist with any inquiries and provide guidance on software setup.

 

Device Features:

 

The IQmark Digital Spirometer was tested at LDS Hospital in Salt Lake City. Below is a summary of the results compared to the spirometry recommendations of the ATS Standardization of Spirometry, 1994 Update.

  • Parameter: FVC Accuracy; ATS: 3.0%; IQmark: Less than 2%
  • Parameter: FVC Precision; ATS: 3.5%; IQmark: Less than 2%
  • Parameter: FEV1 Accuracy; ATS: 3.0%; IQmark: Less than 2%
  • Parameter: FEV1 Precision; ATS: 3.5%; IQmark: Less than 2%
  • Parameter:PEF Accuracy; ATS: 10.0%; IQmark: Less than 5%
  • Parameter: PEF Precision; ATS: 5.0%; IQmark: Less than 2%

 

Specifications: 

 

Real-Time Graphics

  • Flow-Volume
  • Volume-Time

Reports

  • Customizable and Preprogrammed, 8.5 x 11 Full Size

Predicted Equations

  • Crapo (ITS/ATS), NHANES III (Hankinson), Knudson, Morris, Roca, ECCS, Hsu (Pediatric), Polgar (Pediatric), Zapletal (Pediatric)

Interpretation

  • ATS NHANES III (NLHEP)

Calibration

  • 3-Liter Syringe

Power

  • Two 1.5V AAA Alkaline Batteries (serial Version)
  • USB version operates without batteries

Physical Weight & Dimensions

  • Height: 7 inches (2.24 cm)
  • Width: 2.25 inches (7.1 cm)
  • Depth: 1.5 inches (12.7 cm)
  • Weight: 10 oz.

Mouthpiece Resistance

  • 1.043 cmH2O/L/sec @ 14L/sec flow

Meets or Exceeds These Standards

  • American Thoracic Society, Standardization of Spirometry, 1994 Update
  • OSHA-Occupational Safety & Health Administration
  • NIOSH-National Institute for Occupational Safety and Health
  • SSD-Social Security Disability

 

Minimum System Requirements

 

  • Microsoft® Windows®-based PC running Windows 98, or NT version 4.0, 2000/XP or newer with 500MB of disk space available
  • CD-ROM drive, mouse and keyboard
  • Intel® Pentium®-class microprocessor or compatible 500MHz or faster
  • VGA display minimum 256 colors (16-bit recommended)
  • Minimum RAM: 16MB for Windows 98; 32MB for Windows NT; 64MB for Windows 2000/XP
  • One COM port (RS232 serial port or USB port)

 

  • Biomedical Report Included
  • Patient Ready
  • Biomed Tested and Certified 
  • 90 Days warranty

Midmark IQmark - Digital Spirometry System

SKU: 3636
$795.00Price

Midmark IQmark - Digital Spirometry System

 

  • One (1) Refurbished/ Certified - Midmark Iqmark - Digital Spirometer (Patient Ready) (PN: 4-000-0010)
  • Refurbished/ Certified - Midmark IQmark Calibration Syringe (3L) (PN: 1-100-0009)
  • Three (3) Brand New - Midmark Disposable Nose Clips (PN: 2-244-0002)
  • Three (3) Brand New - Midmark Disposable Mouth Pieces
  • One (1) Midmark Syringe Adaptor (PN: 2-100-0043)
  • 8.5 IQ Workstation Manager Software (Ver. 8.5) - Remote Installation Service
bottom of page